- Home
- 2 bedroom apartment
- Where
- Dubai, before handover
- Inspected
- Tuesday 3 November 2026, 10:00 to 12:40
- On the day
- Power, water and air conditioning on. Every room open.
Summary
The home is in good order overall. Four snags should be fixed before you accept it: a split shower seal, a damp patch the thermal camera found above the bedroom ceiling, a dripping sink pipe and a loose balcony railing post. The other six are finishing work your developer should complete.
What we checked
- Walls, floors and ceilingsEvery room, tiles tapped, paint and plaster looked at in raking light2 snags
- Doors and windowsEvery door and window opened, closed and locked, seals and glass1 snag
- Kitchen and wardrobesDoors, drawers, hinges, worktop joints and the appliances supplied2 snags
- Bathrooms and waterTaps run hot and cold, drains, sealant, pipes under every sink2 snags
- Electrics and air conditioningEvery socket tested, every switch and light tried, every room cooling1 snag
- Thermal cameraCeilings, walls around wet rooms, AC grilles and the distribution board1 snag
- BalconyRailing, glass, drainage and tiles1 snag
The snags
1. Main bathroomFix firstShower tray, back cornerSealant split along about 40 cm between the tray and the wall tiles. Water can get behind the tiles.
Ask your developer: Remove and reseal the full length of the tray.
2. Bedroom 2Fix firstCeiling beside the AC grille, thermal cameraThe thermal camera shows a cold, damp patch spreading from the grille. Nothing shows on the paint yet.
Ask your developer: Check the AC drain and duct above the ceiling for a leak, then dry and repaint.
3. KitchenFix firstSink cabinetSlow drip from the waste pipe joint when the tap runs. The cabinet base is already stained.
Ask your developer: Tighten or replace the joint and replace the base if it has swollen.
4. BalconyFix firstRailing, third post from the doorThe post moves by hand and the grout around its base plate has cracked.
Ask your developer: Check the fixings of the post and regrout the base.
5. Living roomMinorFloor by the balcony doorTwo tiles sound hollow when tapped, marked with tape.
Ask your developer: Lift and relay the two tiles.
6. Bedroom 2MinorWardrobe, left doorThe door rubs the frame when it closes and has marked it.
Ask your developer: Adjust the hinges and touch up the frame.
7. HallwayMinorCeiling by the AC grilleHairline crack in the paint, about 30 cm.
Ask your developer: Fill and repaint.
8. Living roomMinorSocket by the TV wallThe double socket sits crooked and is not flush with the wall. It works.
Ask your developer: Refit the socket level and flush.
9. KitchenMinorWorktop joint beside the hobVisible gap and a small step between the two worktop pieces.
Ask your developer: Refill the joint and level the step.
10. Main bedroomMinorWindow, bottom left cornerThe rubber seal has shrunk back from the corner, leaving a gap. Dust is getting in.
Ask your developer: Replace the seal along that side.
What to do next
- Send this report to your developer as it is, before you sign the handover papers.
- Ask for the four snags marked fix first to be done before you take the keys.
- When your developer says everything is fixed, we come back and check every item for AED 400. You get the same report with each snag marked closed or still open.